Instructions (DSF)

Ask for new PVSS license

  1. make sure that your NICE account is added to the database of “Authorised PVSS Users” (if not, ask to the controls coordinator Andre Augustinus and Peter Chochula)
  2. on the PVSS Project Administration panel click on the "get hardware code" button (third from right)
  3. fill the fields on the new panel and send the request
  4. modify the file C:\ETM\PVSS2\3.8\shield with the new licese information

 

Change the password for the Oracle database

SPDFED:

  1. on spdfed0 change all the spd.ini files with the new password (SpdFEDServer and SpdFEDServerP2test)
  2. restart the FED servers

SPD PVSS:

  1. on pcpix108 open Gedi, from the menu on the left select Libraries -> spdConfDataSourceManager.crl
  2. search for the database name ("DEVDB11"), comment the old lines and insert the new password
  3. restart the User Interface, check the log messages

PIT PVSS:

  1. on pxpic106 open Gedi, from the menu on the left select spd_pit -> Libraries -> pit -> pit_database_library.ctl
  2. search for the database name ("DEVDB11"), comment the old lines and insert the new password
  3. restart the User Interface, check the log messages

 

Add FSM parameter

  1. go to Device Editor & Navigator -> FSM tab, chose the "Go to editor" mode, select in the FSM tree the node to be modified (ex. SPD_DCS_RUN) and click on "Create/configure FSM object types"
  2. select the Device Unit to be modified, double click on it
  3. in the new panel, select the Action List (ex. SOR), and click on "Action parameters"
  4. insert the new parameter, click on Add and then OK
  5. do the same with the corresponding Logical Object and save
  6. from the DEV select "Go to navigator" and "Start/restart all"

 

Add equipment on DATE (aldaqpc018)

  1. on aldaqpc018 go to the folder /date/editDb
  2. ./editDb.sh
  3. click on Equipment, select the LDC (ex. aldaqpc018-LDC) and change/add the Equipment (copy the settings from an equipment which is already active)